KENTER Co-Axial Cable is extensively used by leading cable TV companies, surveillance systems installed in areas such as banks, airports, industrial plants, military installations, etc. The central conductor is of solid bare electrolytic graded copper which is 99.97% pure. The name Co-Axial is given as ‘Co’ means ‘Two’ conductors on the same axis. The first conductor is the center copper conductor and the second conductor is provided in form of a metal braid over the insulation over center conductor. At high frequency, the current flows through the skin effect thus copper coated steel wire or copper-coated aluminium wires are also used sometimes. Co-Axial Cables are mainly used for carrying Radio, Audio and Video signals. They act as the lifeline of CATV Network having very low signal loss with an impedance of less than 75 ohms. Aluminium Alloy Wire braiding and aluminium foil are used as shielding from outside interference from motors, fluorescent lights, nearby computers, etc. The outer jacket is of a special UV-resistant PVC compound.
Available in specified RG & UR series as per MIL-C-17 / BS:2316 / IS:5608 / IS : 11967
Suitable for Impedance of 50 / 75 / 100 / 125 ohms
Conductor : Plain / tinned / copper clad steel / Sliver Plated
Insulation : Solid / Foam / Semi air spaced
Screen : Single / Doubled braid
Sheath : PVC / HR PVC / FRLS / P.E.
Construction | Cable Type | ||
Parameters | RG 59 | RG 6 | RG 11 |
Center Conductor | Solid bare Copper | Solid bare Copper | Solid bare Copper |
Nominal Diameter of Conductor | 0.81 mm | 1.02 mm | 1.63 mm |
Dielectric (Insulation) | Foam PE | Foam PE | Foam PE |
Diameter over Insulation | 3.70 mm | 4.60 mm | 7.10 mm |
Outer Conductor 1st Shield 2nd Shield | Al-foil Al-alloy braiding min 60% coverage | Al-foil Al-alloy braiding min 60% coverage | Al-foil Al-alloy braiding min 60% coverage |
PVC Sheath thickness | 0.90 mm | 0.90 mm | 0.90 mm |
Overall Diameter | 6.30 mm | 7.30 mm | 10.30 mm |
Electrical Parameters max. resistance of center in Ohm/100 mtr at 20° C | 3.50 | 2.14 | 0.85 |
Nom. Capacitance PF/mtr | 53 | 53 | 53 |
Characteristic Impedance (Ohm) | 75 | 75 | 75 |
Nom. Velocity Radio | 85 | 85 | 85 |
Attenuation @ 20 C DB/100 mtr at | |||
5 Mhz | 4.02 | 1.95 | 1.25 |
55 Mhz | 6.80 | 5.20 | 3.15 |
211 Mhz | 13.00 | 9.50 | 6.23 |
250 Mhz | 14.0 | 10.50 | 6.72 |
300 Mhz | 15.60 | 11.50 | 7.38 |
350 Mhz | 16.40 | 12.45 | 7.94 |
400 Mhz | 18.00 | 13.30 | 8.53 |
450 Mhz | 19.20 | 14.35 | 9.02 |
550 Mhz | 21.30 | 15.70 | 9.97 |
600 Mhz | 22.05 | 16.45 | 10.43 |
750 Mhz | 25.15 | 18.35 | 11.97 |
870 Mhz | 27.20 | 19.95 | 13.05 |
1000 Mhz (1 Ghz) | 47.00 | 21.45 | 14.27 |